Google's Mandiant says a suspected Chinese state group exploited a 9.8-rated VMware vCenter flaw from early September. Broadcom patched it in November, then fixed a third, related bypass days later. Admins on vCenter 7.0 have no public patch.

Keep exploring
A flaw in the software that runs many companies' virtual servers was used by suspected Chinese state hackers for about two months before anyone could patch it. Then, five days after the fix, Broadcom had to patch a third bug in the same component. If you run VMware vCenter, this is a patch-and-check job, not just a patch job.
The flaw is CVE-2026-123890, a 9.8-rated authentication bypass in vCenter's VMware Directory Service, per The Bootline. Anyone who can reach a vulnerable vCenter over the network can skip authentication and end up with an administrator session, per CyberDelegate. Broadcom lists no official workaround beyond restricting network access, per CyberDelegate. It affects vCenter 8.0, 9.0 and 9.1, plus vCenter inside VMware Cloud Foundation, whether or not Enhanced Linked Mode is used, per The Bootline. The US cyber agency CISA added it to its Known Exploited Vulnerabilities list on November 20, per CyberDelegate.
Google's Mandiant and Threat Intelligence Group attribute the attacks to ARMORY CASTLE, formerly UNC5221, which they describe as a suspected China-nexus espionage group, per iTnews. Attribution of this kind is a judgment by the researchers, and Broadcom itself has not confirmed exploitation, per CyberDelegate. According to Mandiant, the group exploited the bug from early September, before Broadcom's advisory on November 19, per The Bootline. They first broke in through a separate zero-day in BeyondTrust Remote Support appliances, then moved to internal Linux systems and scanned for VMware servers, per CyberDelegate.
A custom tool Mandiant calls BONESAW took vCenter's signing key, forged administrator tokens and created a single sign-on administrator account, per iTnews. It also stole the directory database, per CyberDelegate. A second tool then used stolen SAML keys for "Golden SAML" attacks: forged login tokens that can bypass multi-factor authentication, per CyberDelegate. Mandiant also reported that the group knew about the bug before an earlier, related flaw was disclosed on July 29, per iTnews.
On November 24, Broadcom patched CVE-2026-123903, another 9.8-rated authentication bypass in the same directory service, five days after the exploited one, per iTnews. It is the third vCenter authentication bypass since July. The advisory did not say whether the new flaw has been exploited and offered no workaround. Four separate parties are credited with reporting it, per iTnews. Admins on vCenter 9.1 and 9.0 who patched last week now need 9.1.2 and 9.0.2.0300, while 8.0 users need 8.0 U3m, per iTnews. CyberDelegate notes that Broadcom's newer advisory VMSA-2026-0011 now carries the earlier fixes, so that is the one to follow. Sources differ by a day on the first fix date: The Bootline says November 19, iTnews says November 20.
Because the attackers stole signing keys and directory data, an organization breached before it patched may still be exposed afterward, since forged tokens can keep working until keys are replaced, per CyberDelegate. That reading is CyberDelegate's analysis, so treat it as guidance, not Broadcom's statement.
Update to the fixed builds in the latest advisory and limit who can reach vCenter on the network. Check for unexpected single sign-on administrator accounts and for access to the directory database since early September, per CyberDelegate. vCenter 7.0 has no public patch, and customers need an extended support contract to contact Broadcom, per iTnews. If you run BeyondTrust Remote Support, confirm its fix is in place too, per CyberDelegate.
vCenter controls whole virtualized estates, so admin access there is close to access to everything it manages, per The Bootline. Three authentication bypasses in the same component in four months suggests attackers are finding this area productive. Two zero-days in one campaign, each with purpose-built tools, is the kind of effort that usually points to espionage rather than quick profit, per CyberDelegate. The practical lesson is simple: do not treat a patch as the end of the job on a system this central.
Cover image: VMware HQ campus, Palo Alto by BrokenSphere, CC BY-SA 3.0, via Wikimedia Commons. Archive photo of a VMware office, not from this incident.